The short answer
Polycarbonate can be a good greenhouse covering: it is relatively lightweight, and products such as SUNLITE are impact-resistant. Shortlist multiwall for lower heat loss or clear corrugated sheet for a compatible single-wall system. Choose for your light needs and frame, not thickness alone.
Start with the covering material and a compatible frame/glazing design; then use the detailed polycarbonate comparison below. Film is a separate covering system, not a rigid-panel replacement.
Start with the greenhouse, not a thickness recommendation
For an existing kit, record its model and panel part number before shopping. Measure the panel itself, its edge profile and the receiving channel; a nominal width is not a cut-size instruction. Do not upgrade a kit from one thickness to another unless its maker confirms the replacement and retaining system.
For a new build, write down four decisions:
- Use: an unheated season extender, or a greenhouse you intend to heat?
- Location: roof, wall, door or opening vent? A panel accepted for one location is not automatically a replacement for another.
- Frame: timber or metal, panel dimensions, supported edges and actual support spacing.
- Exposure: the site’s wind and snow design requirements, including the frame, connections and anchoring—not merely the plastic sheet.
SUNLITE’s archived guide separates clamped framing from purlin-supported roofing. There is no thickness-only support-spacing rule.
Choose a covering system before choosing a panel
For seasonal growing, start with how long the greenhouse will be in use. For heated winter growing, include the crop’s heat and light needs. Acrylic and polycarbonate are available as structured sheets; film and glass are different glazing options.
| Covering | When to consider it | Tradeoff to resolve |
|---|---|---|
| Glass | When clear glazing and low routine upkeep matter. | Good light transmission, but heavy and vulnerable to impact. The frame and professional handling plan must suit the glass. |
| Acrylic | When comparing structured rigid-plastic systems. | Specify the product, not just “acrylic.” ACRYLITE Alltop high impact is an impact-modified multi-wall acrylic example, available in grades that block or let through ultraviolet light. Consider it when that light-filtering choice suits your crop plan. It requires its own installation guidance; this is not a specification for all acrylic. |
| Polycarbonate | When a compatible rigid-sheet system is the shortlist. | Use the named sheet comparison below, not the polymer name alone, to choose a specification. |
| Polyethylene film | When a lightweight flexible covering suits the proposed greenhouse. | Plan for recurring replacement and the correct retention system. An inflated double-layer system also needs equipment and maintenance; film is not a drop-in panel. |
Scroll the table horizontally on smaller screens.
Turn the shortlist into a choice. If glass weight or breakage risk is unacceptable, compare documented rigid-plastic grades rather than assuming all plastics perform alike. If periodic re-covering is acceptable, price a complete film system alongside rigid glazing, including replacement access and labor.
For a heated greenhouse, request comparable whole-system heat-loss estimates and light specifications. Match the property and test basis: visible-light transmission is not the same measurement as transmission of light used for photosynthesis. A sheet value alone does not predict heating bills.
Obtain the exact grade/coatings, compatible components, replacement availability, cleaning instructions and limited-warranty terms. Compare installed and recurring costs for your intended use. Have a supplier or qualified designer confirm site loads and the complete assembly; this table does not approve substitutions.
Which panel form fits the job?
A concrete form-factor example: Palram’s US SUNTUF DIY page lists corrugated sheet at 0.032 inch thickness and reports 90% light transmission for its 0.8 mm clear test sheet. That is a single-wall product, not an 8 mm twinwall panel. Its corrugation, closures and fastening system must be matched together. The manufacturer identifies both SUNTUF and SUNLITE as options for a home-built greenhouse; this is an example pair, not a ranking of the market.
Compare thickness and wall structure together
These are selected clear SUNLITE portfolio values on Palram’s US page, not a universal thickness chart or a promise of local stock:
| SUNLITE construction | Nominal thickness | Listed light transmission | Listed U-value, W/m²·K |
|---|---|---|---|
| Twinwall | 6 mm | 80% | 3.5 |
| Twinwall | 8 mm | 80% | 3.3 |
| Twinwall | 10 mm | 79% | 2.9 |
| Triple-wall | 16 mm | 76% | 2.3 |
Scroll the table horizontally on smaller screens.
Lower U-values mean less heat transfer under comparable conditions. Compare wall structure and color as well as thickness. These are sheet specifications, not whole-greenhouse energy or plant-light measurements.
Worked choice: if an installer confirms both options for a proposed heated greenhouse, shortlist 10 mm clear twinwall for its lower U-value; its listed light transmission is one percentage point below 8 mm. Do not make that substitution in an 8 mm-only channel. This is an insulation-focused choice, not a heating-bill prediction.
Do not select tint just because the greenhouse gets hot. Winter light, seasonal shading and ventilation deserve separate consideration. Dirt, structural shading and sun angle also affect the light plants receive.
Three compatibility details that decide whether it works
UV face. Standard SUNLITE has protection on one side; UV2 is a different, two-sided variant. Keep the identification until the outward face is established. For a one-sided sheet, its marked protected face goes toward the sun. “Blocks UV” does not mean either face can be installed outward.
Channel direction and drainage. SUNLITE’s channels run downhill on sloping roofs and vertically on walls. Plan cuts accordingly. Match end tapes and closures to the installation system.
Movement and retention. Polycarbonate expands and contracts. Obtain the specified expansion space, edge engagement, compatible seals and fastening details for the exact sheet and frame. A tight fit is not necessarily a correct fit. Standard SUNLITE’s packaging tape is not its permanent end treatment.
Finish with a purchase specification
Before ordering, you should be able to write:
“I need [maker and grade], [wall structure and thickness], [clear/tint and coating], [verified dimensions and channel direction], for [roof/wall/vent], with [compatible profiles, seals and end treatment], supported by [approved system/design].”
Compare complete installed quotes. If the supplier cannot identify the grade and matching instructions, do not approve the quote. This selection check does not complete attachment, cleaning or service-life questions, or certify the structure. For an attachment method, see the worked greenhouse panel attachment guide.
Palram’s November 30, 2018 guide is distributor-hosted, not verified current. Obtain your product’s current instructions.
Sources
Where this guidance comes from
Checked October 25, 2026.
- Virginia Cooperative Extension — greenhouse coverings and maintenance.
- Palram Americas — panel selection.
- UF/IFAS Extension — glass and film tradeoffs. Checked October 29, 2026.
- UMass Extension — greenhouse use and covering forms. Checked October 29, 2026.
- POLYVANTIS / ACRYLITE — product-specific acrylic example. Checked October 29, 2026.