A water-source heat pump exchanges heat with water on its source side. That water may circulate through a shared building system rather than a well. Start by identifying the loop, not by assuming that “water-source” means geothermal.
Separate source and delivery
The two sides answer different questions: where does the heat come from or go, and how does the room receive heating or cooling?
| Term | What it identifies | What still needs checking |
|---|---|---|
| Water-source | Water supplies or receives heat. | What maintains that water circuit? |
| Water-to-air | The room side exchanges heat with air. | Which rooms or ducts does the unit serve? |
| Water-to-water | The room side uses water. | Which hydronic distribution system is connected? |
An air-to-water heat pump uses outdoor air as its source and water for delivery. A water-source label does not tell you that the rooms have radiators.
Follow one zone
For the water-to-air arrangement described by AAON:
- Cooling: room air passes over the indoor coil. Refrigerant takes up its heat and transfers it to the water circuit.
- Heating: the refrigeration cycle reverses, taking heat from the water and delivering it to the room air.
- Several zones: a cooling zone can add heat that a heating zone uses. Circulation links the units; their room demands need not match.
Identify the loop
| Arrangement | Heat-exchange path | Do not assume |
|---|---|---|
| Closed ground or pond loop | Fluid stays inside buried or submerged piping. | That a nearby pond alone makes a suitable system. |
| Open-water system | Well or surface water passes through the system, then leaves through its permitted return/discharge arrangement. | That available water establishes adequate supply, quality or discharge permission. |
| Shared building loop | Multiple zone units exchange heat with circulating water; central equipment adds or rejects heat. | That each room unit has its own outdoor coil or ground borehole. |
The geothermal guide covers ground-loop project differences. These are architecture distinctions, not instructions to pump, sample, treat or discharge water.
Why a boiler can remain
The room units and central plant have different jobs. A boiler or other heat source can add heat to the loop; a tower or dry cooler can reject excess heat. “Heat pump” does not establish an all-electric building.
Example: a sunlit room needs cooling while a perimeter zone needs heat. Their units can exchange energy through the loop. If the demands do not balance, the shared plant may still need to add or remove heat. This is not a promise that the boiler or tower stays off, or that a particular bill falls.
Read the system record
Use the equipment schedule or building-system diagram to record three things: source circuit, room-side delivery, and equipment maintaining the loop. Keep the room-unit model separate from the central-plant description. If the records only say “heat pump,” the architecture is still unresolved.
Do not open equipment or operate shared valves to identify it. This guide does not size, install or repair a system. For a fault, record the affected rooms and contact the building’s responsible service team rather than changing loop controls.
Sources and limits
Read sources
- Trane: distributed water-loop operation.
- AAON: zone heat exchange.
- BPA HVAC Technology Guide, page 149: water-to-air and water-to-water terminology.
- DOE geothermal consumer guide, page 2: closed-loop and open-loop distinctions.
- Connecticut DEEP: air-to-water distinction.
Checked November 3, 2026. The older technical guides support these physical distinctions, not current prices, incentives, savings, operating limits or product availability.