Use a salt-specific test and keep its result separate from the pool’s chlorine reading. The practical endpoint is a repeatable salinity measurement with its method and units recorded, not an immediate instruction to add salt. This guide gives the Taylor K-1766 drop-test sequence; a different kit does not inherit its sample size or multiplier.
Check what your test measures
AquaChek’s Salt System Test Kit contains separate Yellow 4-in-1 strips and White Salt Titrators. The White titrators measure sodium chloride over 400–7,000 ppm; the other strip covers free chlorine, pH, alkalinity and stabilizer. A reading from the chlorine pad is not a salt reading.
That salt range is the test’s measuring range, not a recommended operating range for every chlorine generator. Match the generator’s own required range separately. If you use AquaChek instead of the drop test below, use the current insert supplied with your exact container; do not transfer Taylor’s drop-count method to a strip.
Run the Taylor drop test
Taylor’s reagent safety sheets call for protective gloves/clothing and eye/face protection if contact is likely; avoid skin/eye contact and breathing mist, and wash after handling. Do not eat, drink or smoke during testing.
For K-1766 with instruction 5031, use its matching reagents. Read their precautions and keep them away from children. Hold dropper bottles vertically.
- Rinse the graduated sample tube, then fill it to 10 mL with the water being tested.
- Add one drop of R-0630 Chromate Indicator and swirl; the sample turns yellow.
- Add R-0718 Silver Nitrate one drop at a time, swirling and counting each drop, until the first change to milky salmon/brick red.
- Multiply the R-0718 count by 200 and record ppm salt as sodium chloride.
A white precipitate forms during the test. Do not keep adding reagent until the sample turns brown: the first specified color change is the endpoint. For example, 16 drops gives 3,200 ppm; this arithmetic is not a generator target or a salt dose. Count the silver-nitrate drops, not the indicator drop.
Make the sample and record usable
Keep the sample container clean and use the collection directions supplied with your test. Record recent salt addition, rain, refill or treatment, because a sample without that context is harder to compare with an earlier result. Do not test a visible pocket of undissolved salt and assume it represents the pool.
| Record | Example of the information needed |
|---|---|
| Kit and reagents | Exact model, reagent IDs, expiry/storage concerns |
| Sample | Date, time, location and recent pool changes |
| Raw observation | Drop count and whether the endpoint was clear |
| Reported result | Value, units and test method |
| Generator | Model, displayed salt value and any warning text |
Never return a reacted test sample to the pool. Follow the reagent labels for handling and disposal; do not mix test reagents with pool-treatment chemicals.
Resolve disagreement before adding salt
| What you find | Next useful action |
|---|---|
| You lost count or passed the endpoint | Start again with a fresh measured sample |
| Two careful tests disagree | Check sample volume, reagent identity, bottle position and endpoint interpretation; obtain a second suitable measurement if unresolved |
| Generator display differs from the manual test | Record both methods, times and units; follow the generator’s diagnostic guidance rather than assuming one number is correct |
| Result cannot be read within the method’s scale | Report the limitation; do not invent a more precise number or an undocumented dilution |
| Salt reading is plausible but chlorine is low | Treat chlorine production and sanitizer measurement as separate questions |
Do not average an obvious testing error into a believable-looking result. A useful handover includes the raw observations, not just “salt is low.”
Finish the measurement, not a treatment
Compare the confirmed result with the exact chlorine generator’s specification. This article does not calculate salt additions, draining, chemical doses or a return-to-swimming decision. Salinity alone does not establish adequate sanitizer, balanced water or bathing safety.
Continue with pool water testing for the wider set of readings and chlorine for sanitizer context. Phosphate testing and six-way-kit procedures are separate methods, not covered by this salt test.